liycy screen cable
UNITRONIC, SCREENED, DATA, SMALL DIMENSIONS, PVC
LiYCY 3x0.75 · Benefits. Overall braid minimises electrical interference · Application range. Screened cables with small dimensions are suitable for use in
Learn MorePDF LiYCY TCWB Screened TP (Twisted Pair) PVC Control Cable - Eland CablesPDF
LiYCY TCWB Screened TP (Twisted Pair) PVC Control Cable A5C technicalspecification| 1 of 2 ISO/IEC 17025 Accredited Testing Laboratory REGULATORY COMPLIANCE This cable is compliant with European Regulation EN 50575, the Construction Products Regulation.
Learn MoreCable Screen LIYCY | PT. Indo Karya Awera Prima
Extensively oil resistant. PVC self-extinguishing and flame retardant according to IEC 60332-1. Technical Data. Temperature Range: Flexing: -5°C to +80°C. Fixed installation: -40°C to +80°C. Nominal voltage: 0,14mm² = 350V > 0,25mm² =500V. Test voltage: core/core 1200 : core/screen 800V. Breakdown voltage: min. 2400V.
Learn MoreNiltox LF-329 LSHF LiYCY Screened Control Cable Number Coded
Stocked on bulk reels, Niltox LF-329 LiYCY control cables can be cut to the length you require, reducing both costs and wastage. These cables feature an aluminium foil screen with a tinned copper wire braid, providing excellent protection from Electromagnetic Interference (EMI).
Learn MoreData & Communication Cables - LiYCY - RR Kabel
Part Number No. of Pairs & Nominal Cross Sectional Area (Sq. mm) Approx. Cable Diame 50300201014 2 x 0.14 4 50300301014 3 x 0.14 4.1 50300401014 4 x 0.14 4.4
Learn MoreLiYCY Screen Cable 2G1.50 – Nicos Fotsios LTD
LiYCY Screen Cable 4G1.00 Quick View Close LiYCY Screen Cable 6G1.00 close categories Accessories 12 Batteries 30 Cable Fittings 68 Cable Managment 195 Cable puller /Soustes 16 Conduit 21 Connectors 32 Plastic Boxes
Learn MoreLAPP KABEL 0034403 - Multicore Cable - element14 Korea
Multicore Cable, Unitronic® LiYCY, Screened, 3 Core, 24 AWG, 0.25 mm², 164 ft, 50 m - Lapp Kabel - 0034403 구매 element14는 특별 가격, 당일 발송,
Learn MoreLiYCY Screened Multicore Number Coded Cable
LiYCY has a tinned copper wire braid screen, providing protection from electromagnetic interference (EMI) and reducing electromagnetic radiation (EMR).
Learn MoreLiYCY - Flexible - screened cables - DDA Ltd
182 rows · LiYCY Flexible screened cable, color coded according to DIN 47100, EMC* Cable structure Stranded bare copper conductor for cross-sections ≥ 0,5 mm 2 according to DIN VDE
Learn MoreTwisted Paired Liycy Shielded Cable for Instrumentation
Screen: Tinned copper wire braid - with tinned copper stranded draining wire (if requested). Sheath: PVC Grey according to RAL 7001 or RAL 7032 on other colors. Minimum Bend Radius: 6 x cable diameter. Temperature range: -30°C to +70°C. Nominal Voltage: 250V. Test Voltage: 26 AWG: 1200V , >26 AWG: 1500V.
Learn MoreProducts Screen Cable LIYCY
For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only
Learn More